高強度封閉式母線槽相關(guān)知識!
該過程不受板的限制,并且外殼被制成華夫餅形式,這增加了匯流排的機械強度,并且匯流排的水平截面可以長達(dá)13m。 由于將外殼制成卷裝形式,因此凹坑的位置被有意地分離和固定,并且母線之間的距離為18 mm。
This process is not limited by the plate, and the shell is made into a waffle shape, which increases the mechanical strength of the bus bar, and the horizontal section of the bus bar can be as long as 13 m. Due to the fact that the enclosure is made into a roll form, the location of the pits is intentionally separated and fixed, and the distance between the busbars is 18 mm.
線路之間的通風(fēng)良好,明顯改善了母線槽的防潮和散熱功能,更適合南方氣候; 它們之間存在一定的間隙,這會導(dǎo)致導(dǎo)線的溫度上升下降,從而提高了過載能力并降低了磁振蕩噪聲。 但是,它產(chǎn)生的雜散電流和電感電抗要比致密的母線大得多,因此與相同規(guī)格的產(chǎn)品相比,其導(dǎo)電條的截面必須大于致密的絕緣插入式母線。
Good ventilation between lines significantly improves the moisture and heat dissipation functions of the bus duct, making it more suitable for the southern climate; There is a certain gap between them, which will cause the temperature of the wire to rise and fall, thereby improving the overload capacity and reducing the magnetic oscillation noise. However, the stray current and inductive reactance generated by it are much larger than that of a dense busbar, so compared to products of the same specification, the cross-section of its conductive bar must be larger than that of a dense insulated plug-in busbar.
空氣插頭母線槽(BMC)
Air plug bus duct (BMC)


由于匯流排之間的接頭與銅軟結(jié)合,南方的天氣潮濕,接頭易于氧化,從而使接頭和匯流排之間接觸不良,從而使接觸點易于加熱,因此 在南方很少使用。 接頭之間的體積太大,水平母線段尺寸不一致,形狀也不美觀。
Due to the soft bonding of the joints between the bus bars and copper, the joints are prone to oxidation in humid weather in the south, resulting in poor contact between the joints and the bus bars, making the contact points easy to heat, so they are rarely used in the south. The volume between joints is too large, the horizontal bus section size is inconsistent, and the shape is not beautiful.
密集絕緣插入式母線槽(CMC)
Densely insulated plug-in bus duct (CMC)
其水分和散熱效果差。 在防潮方面,母線在施工過程中容易受潮和滲水,導(dǎo)致相間絕緣電阻降低。 母線的散熱主要取決于外殼。 由于電線和電線之間的緊湊布置,L2和L3相的熱能被緩慢散發(fā),并且母線槽的溫度升高形成得很高。 致密的絕緣插入式母線受外板限制,只能產(chǎn)生不超過3m的水平截面。 由于匯流排之間的氣隙小,因此當(dāng)匯流排通過大電流時,會產(chǎn)生很強的電功率,導(dǎo)致磁振蕩頻率形成疊加狀態(tài),從而產(chǎn)生過多的噪聲。
Its moisture and heat dissipation effects are poor. In terms of moisture prevention, the busbar is prone to moisture and water seepage during construction, resulting in a reduction in interphase insulation resistance. The heat dissipation of the bus mainly depends on the enclosure. Due to the compact arrangement between the wires and wires, the heat energy of the L2 and L3 phases is slowly dissipated, and the temperature rise of the bus duct is very high. The compact insulated plug-in busbar is limited by the outer plate and can only produce a horizontal cross-section of not more than 3m. Due to the small air gap between the busbars, when the busbars pass through a large current, they generate strong electrical power, resulting in a superimposed state of magnetic oscillation frequencies, resulting in excessive noise.
插入式母線槽為干線式系統(tǒng),具有體積小,結(jié)構(gòu)緊湊,運行可靠,傳輸電流大,分接和送料方便,維護(hù)方便,能耗低,動態(tài)熱穩(wěn)定性好等優(yōu)點
The plug-in bus duct is a trunk type system with advantages such as small size, compact structure, reliable operation, large transmission current, convenient tapping and feeding, convenient maintenance, low energy consumption, and good dynamic thermal stability
上一篇:橋架和線槽的區(qū)分及區(qū)別!
下一篇:鍍鋅電纜橋架設(shè)計注意標(biāo)準(zhǔn)
下一篇:鍍鋅電纜橋架設(shè)計注意標(biāo)準(zhǔn)
相關(guān)文章 / Recommended news
- 鍍鋅橋架是一種用于承載和保護(hù)電纜的結(jié)構(gòu)
- 濟南電纜橋架選購指南:熱鍍鋅與熱浸鋅一字之差,應(yīng)用場景與天壤之別
- 山東工程人必看!橋架安裝驗收7大硬標(biāo)準(zhǔn),少一項都要返工,附詳細(xì)數(shù)據(jù)
- 濟南廠房福音!大跨距橋架破解3大痛點,加強筋加,安裝省一半錢
- 山東工程人警惕!橋架敷線踩這坑必返工,監(jiān)理當(dāng)場叫停,國標(biāo)早有明確規(guī)定
- 濟南人避坑!橋架≠線槽,90%工程人都搞混,一字之差差千里
- 避坑指南!山東電纜橋架規(guī)格別瞎選,偏大浪費偏小隱患大,國標(biāo)早就定好了
- 濟南人必看!鋁合金電纜橋架選對厚度,耐用又省心,90%的人選錯踩坑
- 山東人必看!電纜橋架不是“鐵架子”,藏著建筑用電的密碼,90%的人都不懂
- 800kg/m抗壓!濟南電纜橋架,破解3大工程痛點,工期省30%
陽極氧化鋁合金橋架
托盤式電纜橋架
梯式電纜橋架
梯式不銹鋼電纜橋架
深灰色金屬防火電纜橋架